Deutsch (DE-CH-AT)English (United Kingdom)

MAURER - DIGITAL - 2-COLOR - PYROMETER

Series QKTRD 4085-1

Temperature range 700 to 2500°C (1292 - 4532°F)

Temperature control during production process

compact unit

60 years experiences and digital technology makes it possible!
A pyrometer - as small as a cigarette-box - but powerful like a big one.




KTRD 4000
  • Vario-objective (vario-focus objective)
  • series 44XX with fiber optic cable and objective
  • light beam aiming device with green LED for target
  • emissivity resp. emissivity slope adjustable at the unit
  • analog- und digital output (serial interface)
  • switch-off limit output (open collector)
  • software IR-LOG
Through the serial interface additional parameter functions are possible:
analog output: 0 - 20 / 4 - 20 mA switchable
zoom range within measuring range
emissivity: 100,00 - 10,00 %
average: arithmetical or sliding
maximum value storage: storage modes and erase functions par ex. automatically with the next measuring object
Examples of applications: steel, iron, non-ferrous metal, wires, ceramics, glass feeder, glass tub, glass arching, hardening, rolling, laser, induction heating, brazing, forging, welding, transforming, vacuum furnace




Technical datas:
unit type QKTRD 4085-1
target marking light beam aiming device LED green
temperature range short: TR 1: 700 - 1600°C (1292 - 2912°F) D=85
TR 2: 800 - 2000°C (1472 - 3632°F) D=85
TR 3: 850 - 2500°C (1562 - 4532°F) D=85
Spectral response 0,85 - 1,1 μm
Response time 1 ms dynamical adaption
Accuracy 0,5 % ± 1°C
Reproducibility 1 ‰
Emissivity slope 0,800 - 1,200
Operating temperature 0 - 50°C (32 - 122°F)
Storage temperature -10°C - +70°C (14 - 158°F)
Temperature-sensitivity 0,01 % / °C
Humidity tolerance 35 - 85 % RF
Analog output 0 - 20 mA or 4 - 20 mA
Switch-off limit 5 - 80 %
1 Limit output (open coll.) 24 V 100 mA
Digital output RS 232 ± 50 V isolated
Operating Voltage DC 24 V ± 10 %
Supply current < 100 mA
Unit connection 8-pole plug connector
Dimensions H / W / D 65 x 30 x 80 mm
(2,56 x 1,18 x 3,15 inch)
Weight 0,15 kg (0,33 lbs)
Protection class IP 65


Objectives:
For optimum accomodation to the measuring application an objective with focusing is available. Adjusting range 100 mm to infinite, distance ratio: D = 85
Calculation of target size: focusing distance M mm
distance ratio D


Datasheet KTRD 4085
Datasheet



mechanical assembly electrical assembly electronic process unit
execution in cooling case connection cable 8-pole AED 1012
blowing devices main supply unit 230 VAC 24 VDC AED 1012-C PID controller
mirror 90° digital display AED 1012-PC program controller
mounting parts


 

We use cookies to improve our website and your experience when using it. Cookies used for the essential operation of the site have already been set. To find out more about the cookies we use and how to delete them, see our privacy policy.

I accept cookies from this site.
EU Cookie Directive plugin by www.channeldigital.co.uk