MAURER - DIGITAL - INFRARED - PYROMETER
Series KTRD 1075
Temperature range 250 to 2500°C (482 - 4532°F)
Temperature control during production process
compact unit
Infrared - measuring transducer and electronic process unit in one case 
    
  
  | 
- Vario-objective (vario-focus objective)
 
- light beam aiming device with green LED for target
 
- emissivity adjustable at the unit
 
- analog- und digital output (serial interface)
 
- 1 limit output (open collector)
 
- software IR-LOG
 
 
 | 
 
| Through the serial interface additional parameter functions are possible: | 
 
| analog output: 0 - 20 / 4 - 20 mA switchable | 
 
| zoom range within measuring range | 
 
| emissivity: 100,00 - 10,00 % | 
 
| average: arithmetical or sliding | 
 
| maximum value storage: storage modes and erase functions par ex. automatically with the next measuring object | 
 
 | 
 | 
 
 | 
 | 
 
 | 
 | 
 
| Examples for applications: | 
steel, iron, non-ferrous metal, tempering, coating, wires, hardening, induction heating, soldering, forging, preheating, rolling, glowing etc. | 
 
 
    
  
| Technical datas: |    | 
 
| Unit types | 
KTRD 1075-1 | 
KTRD 1075-2 | 
 
| Target marking | 
light beam aiming device green LED or laser | 
viewfinder | 
 
| Temp. measuring ranges: | 
MR 1: 250 - 1400°C (482 - 2552°F) MR 2: 300 - 2000°C (572 - 3632°F) MR 3: 350 - 2500°C (662 - 4532°F) | 
 
| Spectral range | 
1,45 - 1,7 μm | 
 
| Response time (t90) | 
<0,5 ms | 
 
| Measuring uncertainity | 
0,5 % of meas. value in °C ± 1°C (ε=1, Tu=23°C, T95 = 1s) | 
 
| Reproducibility | 
0,1 % of meas. value in °C ± 1°C (ε=1, Tu=23°C, T95 = 1s) | 
 
| Emission factor ε | 
100 - 10 % adjustable at the unit or through interface | 
 
| Analog output | 
0 - 20 mA oder 4 - 20 mA, load max. 500R | 
 
| Part measuring ranges: | 
free adjustable within the measuring range | 
 
| Resolution | 
<0,1% analog output, <0,1°C at interface | 
 
| 1 limit output (open coll.) | 
24 V DC / max. 100 mA | 
 
| Max. reading memory | 
max.memory, double memory,adjustable time and threshold value,  erasing after time, external contact, by software, after new meas.part | 
 
| Interface | 
RS 232 isolated ± 50 V or RS 485 isolated 2500VRMS  options: PROFIBUS, PROFINET, Ethernet, EtherCAT, USB 2.0 | 
 
| Software IR-LOG | 
data recording, graph. representation, setting of pyrometer parameters | 
 
adjustable parameter with Software IR-LOG | 
emissionfactor,switching output,analog output, part meas.range, °C / °F,  max.memory, average value, light beam aiming device switchable | 
 
| Objectives | 
for accommodation to the measuring application an extensive selection  of objectives are available | 
 
| Working temperature | 
pyrometer 0 - 50°C (32 - 122°F), optic system up to 150°C (302°F) | 
 
| Stock temperature | 
-10°C - +70°C (14 - 158°F) | 
 
| Temperature sensitivity | 
0,05 % / °C | 
 
| Humidity tolerance | 
35 - 85 % RF (non condensing) | 
 
| Operating Voltage | 
24 V DC ± 10 % or 18 V AC ± 10 % < 160 mA | 
 
| Unit connection | 
12-pole plug-connector | 
 
| Dimensions H / W / D | 
54 x 54 x 147 mm (2,13 x 2,13 x 5,79 inch) / ALU-case | 
 
| Weight | 
0,6 kg (1,32 lbs) | 
 
| Protection grade | 
IP 65 | 
 
| Option | 
built in digital display | 
 
 
     Datasheet    
| mechanical assembly |  electrical assembly |  electronic process unit | 
 
| execution in cooling case | 
connection cable 12-pole | 
AED 1012 
  | 
 
| Blowing device | 
power supply 100-270 VAC - 24 VDC | 
AED 1012-C PID controller
  | 
 
| Mirror 90° | 
digital display (built in-execution) | 
AED 1012-PC program controller | 
 
| Mounting parts | 
line scanner SC 1000 / 1012 | 
 | 
 
 | 
PC-Box (USB – connection set) | 
 | 
 
 
   
 |