| MAURER - DIGITAL - INFRARED - PYROMETERSeries KTRD 1065Temperature range 100 to 1400°C (212 - 2552°F)Temperature control during production processcompact unitInfrared - measuring transducer and electronic process unit in one case 
 
 
 
|  | 
Vario-objective (vario-focus objective)light beam aiming device with green LED for targetemissivity adjustable at the unitanalog- und digital output (serial interface)1 limit output (open collector)software IR-LOG |  
| Through the serial interface additional parameter functions are possible: |  
| analog output: 0 - 20 / 4 - 20 mA switchable |  
| zoom range within measuring range |  
| emissivity: 100,00 - 10,00 % |  
| average: arithmetical or sliding |  
| maximum value storage: storage modes and erase functions par ex. automatically with the next measuring object |  
|  |  |  
|  |  |  
|  |  |  
| Examples for applications: | steel, iron, non-ferrous metal, wires, ceramics, rolling, induction heating, soldering, welding, transforming, vacuum furnace etc. |  
 
 
 
| Technical datas: |  |  
| Unit types | KTRD 1065-1 | KTRD 1065-2 |  
| Target marking | light beam aiming device green LED or laser | viewfinder |  
| Temp. measuring ranges: | MR 1: 100 - 800°C (212 - 1472°F) MR 2: 150 - 1200°C (302 - 2192°F)
 MR 3: 200 - 1400°C (392 - 2552°F)
 |  
| Spectral range | 2,1 μm |  
| Response time (t90) | <0,5 ms |  
| Measuring uncertainity | 0,5 % of meas. value in °C ± 1°C (ε=1, Tu=23°C, T95 = 1s) |  
| Reproducibility | 0,1 % of meas. value in °C ± 1°C (ε=1, Tu=23°C, T95 = 1s) |  
| Emission factor ε | 100 - 10 % adjustable at the unit or through interface |  
| Analog output | 0 - 20 mA oder 4 - 20 mA, load max. 500R |  
| Part measuring ranges: | free adjustable within the measuring range |  
| Resolution | <0,1% analog output, <0,1°C at interface |  
| 1 limit output (open coll.) | 24 V DC / max. 100 mA |  
| Max. reading memory | max.memory, double memory,adjustable time and threshold value, erasing after time, external contact, by software, after new meas.part
 |  
| Interface | RS 232 isolated ± 50 V or RS 485 isolated 2500VRMS options: PROFIBUS, PROFINET, Ethernet, EtherCAT, USB 2.0
 |  
| Software IR-LOG | data recording, graph. representation, setting of pyrometer parameters |  
| adjustable parameter with Software IR-LOG
 | emissionfactor,switching output,analog output, part meas.range, °C / °F, max.memory, average value, light beam aiming device switchable
 |  
| Objectives | for accommodation to the measuring application an extensive selection of objectives are available
 |  
| Working temperature | pyrometer 0 - 50°C (32 - 122°F), optic system up to 150°C (302°F) |  
| Stock temperature | -10°C - +70°C (14 - 158°F) |  
| Temperature sensitivity | 0,05 % / °C |  
| Humidity tolerance | 35 - 85 % RF (non condensing) |  
| Operating Voltage | 24 V DC ± 10 % or 18 V AC ± 10 % < 160 mA |  
| Unit connection | 12-pole plug-connector |  
| Dimensions H / W / D | 54 x 54 x 147 mm (2,13 x 2,13 x 5,79 inch) / ALU-case |  
| Weight | 0,6 kg (1,32 lbs) |  
| Protection grade | IP 65 |  
| Option | built in digital display |   Datasheet
 
| mechanical assembly | electrical assembly | electronic process unit |  
| execution in cooling case | connection cable 12-pole | AED 1012 |  
| Blowing device | power supply 100-270 VAC - 24 VDC | AED 1012-C PID controller |  
| Mirror 90° | digital display (built in-execution) | AED 1012-PC program controller 
 |  
| Mounting parts | line scanner SC 1000 / 1012 |  |  
|  | PC-Box (USB – connection set) |  |  |